福祿克Fluke 190-504彩色數(shù)據(jù)示波表
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-062 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke OptiFiber? Pro?OTDR系列
福祿克Fluke CertiFiber?光纖損耗測試套件
福祿克Fluke SimpliFiber? Pro光功率計和光纖測試儀
福祿克Fluke Fiber QuickMap?多模光纖距離和故障定位儀
福祿克Fluke Fiber OneShot? PRO光纖測試儀
福祿克Fluke VisiFault? Visual Fault Locator電纜連通性測試儀
福祿克Fluke MultiFiber? Pro光功率計及光纖測試工具包
福祿克Fluke FI-7000 FiberInspector? Pro光纖顯微攝像機(jī)
NetAlly LinkRunner? G2智能有線網(wǎng)絡(luò)測試儀
NetAlly LinkRunner? AT網(wǎng)絡(luò)自動測試儀
NetAlly OneTouch? AT G2網(wǎng)絡(luò)性能測試儀
NetAlly EtherScope nXG便攜式網(wǎng)絡(luò)專業(yè)智能測試工具
NetAlly LinkRunner 10G高級以太網(wǎng)測試儀
福祿克Fluke LinkIQ?線纜+網(wǎng)絡(luò)測試儀
NetAlly LinkSprinter?口袋便攜式網(wǎng)絡(luò)測試儀
福祿克Fluke EtherScope II網(wǎng)絡(luò)通二代
福祿克Fluke 190-504彩色數(shù)據(jù)示波表
泰克Tektronix MDO3000混合域示波器
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
洞察行業(yè)資訊 分享專業(yè)知識
洞察行業(yè)資訊 分享專業(yè)知識
全國統(tǒng)一服務(wù)熱線:
134 1039 1245
400-996-0787
0755-8399 9818
聯(lián)系郵箱:
sales@faxytech.com
聯(lián)系地址:
深圳市福田區(qū)華強(qiáng)北路華聯(lián)發(fā)大廈602室
部分用戶有需要輸出英文版報告給國外客戶,或者公司內(nèi)部需要英文版報告,或其他語言測試報告的需求,那么應(yīng)該怎樣做才能修改FLUKE測試報告的語言呢?首先不記得怎么導(dǎo)出FLUKE測試報告的同學(xué)可以點擊下面鏈接回顧一下如何導(dǎo)出測試報告。其次我們要有FLUKE的報告管理軟件,還沒有軟件的同學(xué)看這個下載地址:(點擊下載)更改FLUKE測試報告的語言其實很簡單的,我們管理測試報告使用的是FLUKE LinkWare軟件,更改FLUKE報告語言的原理是FLUKE LinkWare軟件本身設(shè)置的語言是什么,它輸出的報告就是什么語言。關(guān)于怎么修改FLUKE LinkWare軟件本身的語言,其實只要記住這個語言設(shè)置的位置,無論FLUKE LinkWare軟件是什么語言,都可以改成咱們想要的語言,并輸出報告。英文版軟件更改語言步驟:1、選擇“Options”。2、選擇最后一項,“Language”。3、選擇您需要變更的語言。中文版軟件更改語言步驟:1、選擇“選項”。2、選擇最后一項,“Language”。3、選擇您需要變更的語言。最后只需要點擊輸出為PDF按鈕就完成。...
許多技術(shù)小伙伴雖然已經(jīng)使用了很久FLUKE電纜測試儀,但是對FLUKE的測試標(biāo)準(zhǔn)文件與測試報告還是一知半解,今天我們來一個一個講清楚。經(jīng)常有客戶問,儀器內(nèi)置的測試標(biāo)準(zhǔn)(也叫測試極限值)指標(biāo)是多少,我線的參數(shù)要達(dá)到多少dB才能過測試呢?這可以查看FLUKE儀器內(nèi)置測試標(biāo)準(zhǔn)文檔,下圖是文檔中的截圖,這個是TIA CAT 6 Perm.Link測試標(biāo)準(zhǔn)的具體測試項目與指標(biāo)。如何看測試標(biāo)準(zhǔn)文檔?首先我們要明確,圖中所有的信息是針對TIA CAT 6 Perm.Link這個標(biāo)準(zhǔn)的,表中的信息不一定適用于其他標(biāo)準(zhǔn),每個標(biāo)準(zhǔn)有自己的測試通過規(guī)則,每句話對應(yīng)左側(cè)的顏色,左側(cè)的顏色代表右側(cè)的參數(shù),并且在不同的工作頻率下,每項參數(shù)的指標(biāo)是不一樣的,所以圖表上只是標(biāo)出了部分頻率下每項參數(shù)的指標(biāo)。重點信息解讀:i字母代表僅供參考的信息,標(biāo)準(zhǔn)不對這項參數(shù)做要求。在儀器界面中是這樣顯示:淺藍(lán)色代表Length(長度),對長度的特別說明:長度大于99米就不達(dá)標(biāo),測試失敗。淺黃色代表標(biāo)準(zhǔn)不要求檢測的項目,在圖中代表ACR-N和PS ACR-N。紫色代表RL(回波損耗),有個特殊情況:如果插入損耗小于3dB,這項參數(shù)直接忽略不做要求,也就是無論測出來是多少,都直接過。綠色代表ACR-F(遠(yuǎn)端衰減串?dāng)_比),有個特殊情況:如果FEXT(遠(yuǎn)端串?dāng)_)小于67dB,這項參數(shù)直接忽略不做要求,也就是無論測出來是多少,都直接過。FLUKE報告看不懂,如何解讀測試報告?我們先來看整體,再分解詳談。報告頁頭:這里看到測試設(shè)置與儀器和適配器信息。報告左側(cè):福祿克測試會把線纜在所有工作頻率下的各項參數(shù)都測出來,如果是超五類網(wǎng)線標(biāo)準(zhǔn),那么超五類網(wǎng)線的工作頻率是0~100Mhz,如果不算小數(shù)點只算整數(shù)也有100個點,按理說要把13項數(shù)據(jù)的100個數(shù)據(jù)都寫在一張紙上,這么點地方肯定寫不下呀,應(yīng)該怎么解決這個問題呢?我們來看看福祿克報告是怎么做的。其實就是木桶原理,我們只看最短的那個板,考核它,看它達(dá)不達(dá)標(biāo),如果全班最差的學(xué)生都能考上清華北大,那其他學(xué)生的成績就不用擔(dān)心了。福祿克測試報告上寫的就是每項參數(shù)最差的那個值,拿這個最差的值與極限值(標(biāo)準(zhǔn)值)做對比,如果最差的都過了,那這項參數(shù)就通過測試。這個表格里面還有2個很重要的概念:最差值和最差余量。最差值,顧名思義,就是某頻率(橫向坐標(biāo))測試結(jié)果最差的那個線對的值,一般是縱向坐標(biāo)的最低點。咱們還是拿考試舉例,一個學(xué)期10次考試,最差值就是考的最差的那次。最差余量呢,余量(Margin)就是各性能指標(biāo)測量值與測試標(biāo)準(zhǔn)極限值的差值,正余量表示比測試極限值好,結(jié)果為PASS,負(fù)值表示測試極限值差,結(jié)果為FALL,余量越大,說明距離極限值越遠(yuǎn),性能越好。繼續(xù)拿考試舉例,假設(shè)及格線60分,我如果考了70分,余量就是70-60=10分,我如果考了40分,余量就是40-60=-20分,所以余量是越大越好的。最差余量有兩種情況,一種是在整個頻率上距離測試極限值最近的點;另一種是所有線對余量最差的線對。由于極限值大多數(shù)情況下在各個頻率上是不一樣的,一般都是曲線,所以最差值和最差余量很有可能不在同一個頻率點上。報告右側(cè):每項參數(shù)的波形圖,橫坐標(biāo)是頻率Mhz,縱坐標(biāo)是dB,紅色線是標(biāo)準(zhǔn)線,如果低于標(biāo)準(zhǔn)線,則測試失敗。...
最近有特別多的客戶,多到什么地步,十個客戶有九個咨詢,為啥我的FLUKE熱像儀連不上電腦捏?這純純的就是FLUKE電腦端軟件適配的問題,與儀器沒關(guān)系,下面我們教大家解決這個問題。解決這個問題前,我們先科普一下FLUKE熱像儀的2款軟件,分別是Fluke Connect 與SmartView。Fluke Connect是FLUKE新推出的電腦端熱像圖分析軟件,雖然是新軟件,但是功能不如SmartView多,而且容易出BUG,我個人不是很推薦。SmartView是FLUKE一直以來的熱像儀分析軟件,很多年了,功能全面,使用穩(wěn)定,比較推薦使用這款軟件。1、從FLUKE官網(wǎng)下載軟件建議用戶自行從福祿克官網(wǎng)上下載最新的電腦端軟件,特別是想用SmartView的用戶,以我們之前的經(jīng)驗來看,用戶安裝由我們提供的最新版SmartView,儀器怎么也連不上電腦,但是用戶自行去官網(wǎng)下載的安裝后就是可以連上,很多個客戶都出現(xiàn)這樣的情況了,非常玄學(xué)!FLUKE官網(wǎng)軟件下載鏈接:(點擊下載)2、安裝軟件2遍?。⊿martView需要裝2遍,F(xiàn)luke Connect不用裝2遍)右鍵安裝包,選擇“以管理員身份運行”安裝軟件2遍,裝好以后馬上再裝一遍,并且在裝的過程中把360安全衛(wèi)士這類的電腦管家關(guān)閉!你問我為什么要裝2遍,我也不知道,但就是有用,問就是玄學(xué)。3、禁用驅(qū)動程序強(qiáng)制簽名在不同的系統(tǒng)有不同的禁用操作方法,大家可以在百度上自行搜索一下,按照教程操作。4、檢測更新電腦驅(qū)動下載安裝驅(qū)動精靈這類的驅(qū)動管理軟件,檢測一下電腦有沒有缺少驅(qū)動,把電腦的驅(qū)動都更新到最新狀態(tài)。5、更換供電充足的USB接口筆記本電腦就更換其他USB接口,臺式電腦就使用主機(jī)背后主板上的USB接口,這樣供電充足。6、更換電腦更換其他電腦重復(fù)上面操作,有些用戶的電腦被公司禁止了某些功能,導(dǎo)致儀器連接不上軟件,這時候就可以更換其他權(quán)限不受限的電腦試一下。如果按照上面的方法還是無法連接儀器,您可以隨時聯(lián)系我們的免費熱線咨詢噢~...
在選擇鉗表的時候,最常聽到的問題大多是“精度怎樣“,”準(zhǔn)不準(zhǔn)“。影響鉗表準(zhǔn)確性的因素很多,設(shè)計/做工、帶寬、頻率響應(yīng)、包括是否選擇了適合的量程,均會對讀數(shù)造成影響。然而所有這些因素中,最重要的因素之一,便是真有效值測量,特別是對電氣設(shè)備種類繁多,電氣環(huán)境復(fù)雜的工業(yè)類用戶。非真有效值,也就是平均值響應(yīng)的儀表,主要是針對標(biāo)準(zhǔn)工頻的正弦波的測量。常見的實現(xiàn)原理,是將測得的算數(shù)平均值讀數(shù)x1.1,轉(zhuǎn)化成正弦波的‘有效值‘讀數(shù)。在電氣化環(huán)境比較單純的環(huán)境,這是完全沒問題的,比如樓宇物業(yè)等。而更為廣泛的工業(yè)環(huán)境,特別是越來越多的變頻、整流器、逆變器等設(shè)備的使用,實際的波形越來越多樣化,甚至引入了越來越多的高頻噪聲,因此要準(zhǔn)確測量,真有效值成為其中最重要的因素之一。我們來看一看如下的示意圖就秒懂了:提到噪聲或著諧波,不得不說另外一個重要的概念:低通濾波器(LPF)。言下之意,只有低頻電流電壓才能被測算,高頻的部分就會被截至不予計算??梢哉f,只有具備了低通濾波的真有效值鉗表,才是真正有價值的‘真有效值‘。福祿克真有效值鉗表,全系真有效值鉗表*均配備800-900Hz低通濾波器,部分型號比如Fluke 369/368,安博ACD-14 PRO更是配備了60~70Hz截至的工頻低通濾波器(BP)(* 僅F-323, T6系列未配置)。鑒于真有效值對鉗表如此重要福祿克在今年特別推出了F325/324/323系列400A真有效值鉗表文章來源:摘自網(wǎng)絡(luò)...
WARNING: This will delete ALL results and settings, there is no way to undo this.需要特別提醒的是:恢復(fù)過程當(dāng)中將會導(dǎo)致所有的儀器設(shè)置和原來內(nèi)置的測試報告均將丟失,并且這不是一個可逆的操作過程。This feature is for rental companies and locations where data is considered sensitive. It will not wipe out any information on a thumb drive attached to the Versiv (TFS) unit. If you have access to YouTube, you can watch how to do it here.Tap Tools followed by Memory Status. Touch the parts of the screen in the order shown below:You will then see a Restore Defaults button appear.Tap this for a final warning about doing this:The Versiv (TFS) will then play a tune and reboot....
儀器內(nèi)部發(fā)出“咔咔”聲是熱像儀自動校準(zhǔn)引起的,通常發(fā)生在熱像儀快速移動;剛開機(jī)。自校原因:熱像儀會根據(jù)環(huán)境溫度變化,自動調(diào)整以抵消該變化對探測器準(zhǔn)確性的影響,該過程一般持續(xù)2~3 秒,屏幕出現(xiàn)停滯并顯示“正在校準(zhǔn)”。...
福祿克DTX-1800測試報告中ACR-N顯示N/A,而不是PASS或者Fail,如下圖所示:(在Linkware軟件測試報告中的其他設(shè)備同理)如果你正在測試任何ANSI/TIA標(biāo)準(zhǔn),你將會總是看到N/A出現(xiàn)在ACR-N測試指標(biāo)欄目里面,因為ACN-N不是ANSI/TIA要求測試參數(shù)。但是因為許多客戶比較關(guān)注ACR-N這個指標(biāo),所以福祿克在測試的時候,會測試這個參數(shù),并且標(biāo)注出來,為了特別工程師的需求。值得一提的是ISO/IEC標(biāo)準(zhǔn)是需要測試ACR-N的。ISO/IEC標(biāo)準(zhǔn)測試出現(xiàn)N/A的時候,一般是使用永久鏈路進(jìn)行測試時候,并且插入損耗小于4db。通道測試就不會??偨Y(jié):這個沒有對不對,你的設(shè)備(DTX-1800)測試只是根據(jù)你選擇的標(biāo)準(zhǔn)來判斷的??傮wPASS就是合格。...
A YouTube video explaining how this this works is also?available from here.This is applicable to the following cabling standards only:ISO/IEC 11801EN 50173Aus/NZJISWhen?the Insertion Loss is less than 4.0 dB at the frequency point where the measurement is made, then the measurement is ignored and not uated against the selected Test Limit/Cabling Standard in the DTX CableAnalyzer. This is often referred to as the 4 dB rule. It is not applied in the North American TIA Cabling Standards. Only certain test parameters and configurations will have the 4 dB rule. The tables below indicate which link? definitions and test parameters have the 4 dB rule applied to them. As an aid, the other rules are also listed.On a?short link, the Insertion Loss may never reach 4.0 dB. If that were to happen, then the entire measurement would be?ignored, or as the cabling standards phrase it; “recorded for information only”. If this were to happen with your DTX CableAnalyzer, you would see an “i” appear next to the summary result for that test parameter. In LinkWare software, the result would be recorded with “N/A’. An example is shown below:Concern is normally caused when the result has a negative margin. In this example we see the NEXT margin was -9.7 dB. A?negative margin is normally associated with a FAIL, but because the entire link never exceeded 4.0 dB Insertion Loss, it’s not a FAIL. Further?confusion lies in that the North American ANSI/TIA/-568-C.0 cabling standard does not have this 4 dB rule. If you were to test the same link above?with the same DTX CableAnalyzer, but using the North American Standard TIA Cat 5e Perm. Link, your result would be a FAIL.Please make sure you?have agreed in a Test Limit, in writing, before the project starts.Let’s review in detail how this works by looking at another example test result on the DTX CableAnalyzer.An ISO11801 PL Max Class D AUTOTEST was run on a short 6.0 m installed link, giving the following result:Looks normal. Let’s take a look at the NEXT result in a little more detail:You will observe that?the limit line has two colors, black and red. The cabling standards do not require the cable tester manufacturer to display where the 4 dB rule is implemented to the user, only that it is implemented. However, the DTX CableAnalyzer will indicate where the 4 dB rule has been implemented by changing the color of the limit line. If the?limit line is black,?the Insertion Loss was less than 4.0 dB. If?the limit line is red,?the Insertion Loss was 4.0 dB or greater. So for this Pair 1,2-4,5 the NEXT is not uated below 84.8 MHz. Let’s take a quick look at the Insertion Loss for Pair 4,5:As you can see, the Insertion Loss reached 4.0 dB at 84.8 MHz, as previously indicated in the NEXT Pair 1,2-4,5 graph above. NEXT contains two pairs. So which Insertion Loss pair do we use to implement the 4 dB rule? The disturbed pair is used for uation purposes. So if the worst case NEXT Pair was 1,2-7,8 then the?DTX CableAnalyzer would use the Insertion Loss values from Pair 7,8 to determine where the 4 dB rule is implemented.As previously mentioned, if the link is particularly short, then the Insertion Loss may never reach 4.0 dB and the entire NEXT result is “ignored”. Let’s take a closer look at the first example where the test result was:Looking at the worst case NEXT result, we see the entire limit line is black, suggesting that the Insertion Loss for Pair 4,5 never reached 4.0 dB:Looking at the Insertion Loss for Pair 4,5:We see that the Insertion did indeed never reach 4.0 dB, so the entire measurement is not uated against the limit line (ignored) and recorded as “i” Information Only. If this result was downloaded to LinkWare Software, the report would show N/A against this measurement:No further action is required by the installer. This is a valid standards compliant result....
Copyright? 1998-2023深圳市連訊達(dá)電子技術(shù)開發(fā)有限公司 All Rights Reserved .
地址:深圳市福田區(qū)華強(qiáng)北路華聯(lián)發(fā)大廈602室 客服:400-966-0787
備案號:
粵ICP備18089363號
網(wǎng)站地圖
免責(zé)聲明:福祿克、FLUKE、FLUKE NETWORKS、 NETALLY等品牌資料及圖片摘自網(wǎng)絡(luò),連訊公司不擁有以上品牌商標(biāo)及相關(guān)產(chǎn)品著作權(quán)。